PVC Duct Pipes — DIN 8062
Premium Manufacturer & Supplier in the UAE
Metric duct pipes to DIN 8062 — PN 4 to PN 16, 20–315 mm.
Standards & Certifications
Overview
Product introduction and key characteristics
Crown Plastic Pipes / Fittings, a trusted metric duct pipe supplier in the UAE, produces PVC-U duct pipes to DIN 8062 standards. Available in pressure classes from PN 4 to PN 16 with sizes from 20 mm to 315 mm, these pipes serve the demanding cable protection requirements of industrial, commercial, and municipal projects across the UAE. Manufactured at our ISO 9001:2015 certified Umm Al Quwain facility.
Features
Technical advantages and key benefits of this product range
- Compliance with NEMA TC 2, TC 6 & 8, and ASTM F 512 standards
- Standard sizes available in both Metric (DIN 8062) and Imperial (BS 3505/06) dimensions
- Specific formulations for normal duty (EPC 40) and heavy-duty (EPC 80) applications
- Specialized designs for Encased Burial (EB) and Direct Burial (DB) requirements
- Available in standard lengths of 5.8 meters or customized to project requirements
- Manufactured in standard colors including Black and Dark Grey
Applications
Ideal use cases and industries for this product
- Underground telecommunications infrastructure following Etisalat & DU specifications
- Electrical wire and cable protection for underground installations
- Concrete-encased and direct burial electrical tubing and conduits
- Street lighting and utility network ducting for major urban developments
Pipe Specifications
Technical dimensions and parameters for all pipe sizes
DIN 8062 Metric size Pressure Pipes
| Nominal Size mm | Mean Outside Dia. | Mean Wall Thickness | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Min | Max | PN-16 (CLASS-16) | PN-10 (CLASS-10) | PN-6 (CLASS-6) | PN-4 (CLASS-4) | |||||
| Min | Max | Min | Max | Min | Max | Min | Max | |||
| 20 mm | 20.0 | 20.2 | 1.5 | 1.9 | - | - | - | - | - | - |
| 25 mm | 25.0 | 25.2 | 1.9 | 2.3 | 1.5 | 1.8 | - | - | - | - |
| 32 mm | 32.0 | 32.2 | 2.4 | 2.9 | 1.8 | 1.9 | - | - | - | - |
| 40 mm | 40.0 | 40.2 | 3.0 | 3.5 | 1.9 | 2.3 | 1.8 | - | - | - |
| 50 mm | 50.0 | 50.2 | 3.7 | 4.3 | 2.4 | 2.9 | 1.8 | - | - | - |
| 63 mm | 63.0 | 63.2 | 4.7 | 5.4 | 3.0 | 3.4 | 1.9 | - | - | - |
| 75 mm | 75.0 | 75.3 | 5.6 | 6.4 | 3.6 | 4.2 | 2.2 | - | 1.8 | 2.2 |
| 90 mm | 90.0 | 90.3 | 6.7 | 7.6 | 4.3 | 5.1 | 2.7 | - | 1.8 | 2.3 |
| 110 mm | 110.0 | 110.3 | 8.2 | 9.3 | 5.3 | 5.9 | 3.2 | - | 2.2 | 2.6 |
| 125 mm | 125.0 | 125.3 | 9.3 | 10.3 | 6.0 | 6.8 | 3.7 | - | 2.5 | 2.9 |
| 140 mm | 140.0 | 140.4 | 10.4 | 11.8 | 6.7 | 7.5 | 4.1 | - | 2.8 | 3.3 |
| 160 mm | 160.0 | 160.4 | 11.9 | 11.3 | 7.7 | 8.5 | 4.7 | - | 3.2 | 3.8 |
| 180 mm | 180.0 | 180.4 | 13.4 | 15.0 | 8.6 | 9.4 | 5.3 | - | 3.6 | 4.2 |
| 200 mm | 200.0 | 200.4 | 14.9 | 16.6 | 9.6 | 10.7 | 5.9 | - | 4.0 | 4.4 |
| 225 mm | 225.0 | 225.5 | 16.7 | 18.6 | 10.8 | 11.6 | 6.6 | - | 4.5 | 4.9 |
| 250 mm | 250.0 | 250.5 | 18.6 | 20.7 | 11.9 | 13.3 | 7.3 | - | 4.9 | 5.7 |
| 280 mm | 280.0 | 280.5 | 20.8 | 23.1 | 13.4 | 14.9 | 8.2 | - | 5.5 | 6.3 |
| 315 mm | 315.0 | 315.6 | 23.4 | 26.0 | 15.0 | 16.7 | 9.2 | 10.4 | 6.2 | 7.1 |
Installation Guidelines
Best practices for optimal performance and longevity
Do's
- ✓Use EPC 40 for normal duty above ground or concrete-encased applications
- ✓Select EPC 80 for heavy-duty applications requiring higher wall thickness
- ✓Ensure EB type ducts are encased in concrete during installation
- ✓Utilize DB type ducts for direct burial without the need for concrete encasement
Don'ts
- ✗Do not use EB series ducts for direct burial applications without concrete encasement
- ✗Avoid using Class-O (non-pressure) pipes for applications requiring specified working pressures
- ✗Do not exceed the specified working pressure ratings for PN series pipes at 20°C
- ✗Avoid mismatched accessories; use standard duct sockets, end caps, and bellmouths for secure connections
Technical FAQs
Answers to common questions about this product
- Compliance with NEMA TC 2, TC 6 & 8, and ASTM F 512 standards
- Standard sizes available in both Metric (DIN 8062) and Imperial (BS 3505/06) dimensions
- Specific formulations for normal duty (EPC 40) and heavy-duty (EPC 80) applications
- Specialized designs for Encased Burial (EB) and Direct Burial (DB) requirements
- Available in standard lengths of 5.8 meters or customized to project requirements
- Manufactured in standard colors including Black and Dark Grey
- Use EPC 40 for normal duty above ground or concrete-encased applications
- Select EPC 80 for heavy-duty applications requiring higher wall thickness
- Ensure EB type ducts are encased in concrete during installation
- Utilize DB type ducts for direct burial without the need for concrete encasement
- Do not use EB series ducts for direct burial applications without concrete encasement
- Avoid using Class-O (non-pressure) pipes for applications requiring specified working pressures
- Do not exceed the specified working pressure ratings for PN series pipes at 20°C
- Avoid mismatched accessories; use standard duct sockets, end caps, and bellmouths for secure connections
Technical Documents
Access comprehensive technical catalogues, dimensional specifications, and compliance documentation for PVC Duct Pipes — DIN 8062.
Need assistance with PVC Duct Pipes — DIN 8062?
Our technical team is here to help you select the right products for your project.