PVC Duct Pipes

PVC Duct Pipes — DIN 8062

Premium Manufacturer & Supplier in the UAE

Metric duct pipes to DIN 8062 — PN 4 to PN 16, 20–315 mm.

Standards & Certifications

DIN 8062
Crown Plastic Pipes
Premium Quality
ISO 9001:2015 Certified
GCC Market Leader
52+ Countries
UV & Weather Resistant
High Impact Strength
Corrosion Free
Low Maintenance Life
DIN 8062

Overview

Product introduction and key characteristics

Crown Plastic Pipes / Fittings, a trusted metric duct pipe supplier in the UAE, produces PVC-U duct pipes to DIN 8062 standards. Available in pressure classes from PN 4 to PN 16 with sizes from 20 mm to 315 mm, these pipes serve the demanding cable protection requirements of industrial, commercial, and municipal projects across the UAE. Manufactured at our ISO 9001:2015 certified Umm Al Quwain facility.

Features

Technical advantages and key benefits of this product range

  • Compliance with NEMA TC 2, TC 6 & 8, and ASTM F 512 standards
  • Standard sizes available in both Metric (DIN 8062) and Imperial (BS 3505/06) dimensions
  • Specific formulations for normal duty (EPC 40) and heavy-duty (EPC 80) applications
  • Specialized designs for Encased Burial (EB) and Direct Burial (DB) requirements
  • Available in standard lengths of 5.8 meters or customized to project requirements
  • Manufactured in standard colors including Black and Dark Grey

Applications

Ideal use cases and industries for this product

  • Underground telecommunications infrastructure following Etisalat & DU specifications
  • Electrical wire and cable protection for underground installations
  • Concrete-encased and direct burial electrical tubing and conduits
  • Street lighting and utility network ducting for major urban developments

Pipe Specifications

Technical dimensions and parameters for all pipe sizes

DIN 8062 Metric size Pressure Pipes

Nominal Size mmMean Outside Dia.Mean Wall Thickness
MinMaxPN-16 (CLASS-16)PN-10 (CLASS-10)PN-6 (CLASS-6)PN-4 (CLASS-4)
MinMaxMinMaxMinMaxMinMax
20 mm20.020.21.51.9------
25 mm25.025.21.92.31.51.8----
32 mm32.032.22.42.91.81.9----
40 mm40.040.23.03.51.92.31.8---
50 mm50.050.23.74.32.42.91.8---
63 mm63.063.24.75.43.03.41.9---
75 mm75.075.35.66.43.64.22.2-1.82.2
90 mm90.090.36.77.64.35.12.7-1.82.3
110 mm110.0110.38.29.35.35.93.2-2.22.6
125 mm125.0125.39.310.36.06.83.7-2.52.9
140 mm140.0140.410.411.86.77.54.1-2.83.3
160 mm160.0160.411.911.37.78.54.7-3.23.8
180 mm180.0180.413.415.08.69.45.3-3.64.2
200 mm200.0200.414.916.69.610.75.9-4.04.4
225 mm225.0225.516.718.610.811.66.6-4.54.9
250 mm250.0250.518.620.711.913.37.3-4.95.7
280 mm280.0280.520.823.113.414.98.2-5.56.3
315 mm315.0315.623.426.015.016.79.210.46.27.1

Installation Guidelines

Best practices for optimal performance and longevity

Do's

  • Use EPC 40 for normal duty above ground or concrete-encased applications
  • Select EPC 80 for heavy-duty applications requiring higher wall thickness
  • Ensure EB type ducts are encased in concrete during installation
  • Utilize DB type ducts for direct burial without the need for concrete encasement

Don'ts

  • Do not use EB series ducts for direct burial applications without concrete encasement
  • Avoid using Class-O (non-pressure) pipes for applications requiring specified working pressures
  • Do not exceed the specified working pressure ratings for PN series pipes at 20°C
  • Avoid mismatched accessories; use standard duct sockets, end caps, and bellmouths for secure connections

Technical FAQs

Answers to common questions about this product

  • Compliance with NEMA TC 2, TC 6 & 8, and ASTM F 512 standards
  • Standard sizes available in both Metric (DIN 8062) and Imperial (BS 3505/06) dimensions
  • Specific formulations for normal duty (EPC 40) and heavy-duty (EPC 80) applications
  • Specialized designs for Encased Burial (EB) and Direct Burial (DB) requirements
  • Available in standard lengths of 5.8 meters or customized to project requirements
  • Manufactured in standard colors including Black and Dark Grey
  • Use EPC 40 for normal duty above ground or concrete-encased applications
  • Select EPC 80 for heavy-duty applications requiring higher wall thickness
  • Ensure EB type ducts are encased in concrete during installation
  • Utilize DB type ducts for direct burial without the need for concrete encasement
  • Do not use EB series ducts for direct burial applications without concrete encasement
  • Avoid using Class-O (non-pressure) pipes for applications requiring specified working pressures
  • Do not exceed the specified working pressure ratings for PN series pipes at 20°C
  • Avoid mismatched accessories; use standard duct sockets, end caps, and bellmouths for secure connections

Technical Documents

Access comprehensive technical catalogues, dimensional specifications, and compliance documentation for PVC Duct Pipes — DIN 8062.

Need assistance with PVC Duct Pipes — DIN 8062?

Our technical team is here to help you select the right products for your project.